Preformed Dead End Guy Grip

Short Description:

Preformed Tension Clamp are designed to connect ADSS cables and poles/towers . Armor rods can provide protection and cushioning to the ADSS cables. The special design of Preformed rods makes ensure that Tension Clamps can’t cause undue stress to the ADSS cables, so as to ensure the normal lifetime of cables system.

Tension Clamp are designed to connect OPGW cables and tensile poles (or towers). Armor rods can protect and provide cushioning to the OPGW cables. The special design of Armor rods makes ensure that Tension Clamps can not cause undue stress to the OPGW cables,so that the normal lifetime of cable system is ensured.

It is used for the branch connection of insulated cables in building power distribution systems, the connection of low-voltage overhead insulated cables, the branch connection of low-voltage insulated household cables, and street lamp power distribution systems.


Product Detail

Product Tags

Overview

Tension Clamps are designed to connect ADSS cables and poles/towers . Armor rods can provide protection and cushioning to the ADSS cables. The special design of Preformed rods makes ensure that Tension Clamps can’t cause undue stress to the ADSS cables, so as to ensure the normal lifetime of cables system.

Preformed Tension Clamp are designed to connect ADSS cables and poles/towers . Armor rods can provide protection and cushioning to the ADSS cables. The special design of Preformed rods makes ensure that Tension Clamps can’t cause undue stress to the ADSS cables, so as to ensure the normal lifetime of cables system.

Tension Clamp are designed to connect OPGW cables and tensile poles (or towers). Armor rods can protect and provide cushioning to the OPGW cables. The special design of Armor rods makes ensure that Tension Clamps can not cause undue stress to the OPGW cables,so that the normal lifetime of cable system is ensured.

1

Matching hardware

Heart-shaped ring (picture 1-1) (table 1-1) (circle 1-2) (table 1-2)
Body: Hot-dip galvanized ductile iron Bolt: Made of hot-dip galvanized steel
Split pin: stainless copper
Heart-shaped ring

Product number

Reference mark

Breaking strength

weight
(kg)

Size (mm)

A

B

C

D

E

TC-12

TC-12

120

0.9

107

48

24

57

M16

TC-16

TC-16

156

1.7

124

57

25.4

64

M18

TC-16

TC-16

156

1.7

124

57

25.4

64

M16

Heart ring

Product number

Reference mark

Breaking strength

weight
(kg)

Size (mm)

A

B

C

D

E

TC-05

TC-05

50

0.33

60

45

20

40

16

TC-07

TC-07

70

0.44

60

45

20

42

16

Note
▪ Do not overlap the wire clips. Lapping on the wires before and after the clamp is allowed:
▪ Do not use wire clamps for overhead ground wires;
▪ After the initial installation, do not use the wire clamp again:
▪ The direction of rotation of the wire clamp and the wire should be the same. The standard clamp is right-handed, if you need left-handed products, please consult the company.

Selection table of strain clamp for pre-twisted insulated conductors (1)

Product number

Applicable wire diameter range (mm)

Applicable wire model below 1kV

GB12527-90

Applicable wire model below 10kV

GB 14049-93 thin insulation

Reference length

(mm)

Color code

Optional matching hardware

The smallest

maximum

DN-3510

5.82

6.53

10

460

Orange

TC-05

DN-3511

6.55

7.34

16

530

yellow

DN-3513

8.28

9.25

25

690

green

DN-3514

9.26

10.39

35

690

yellow

DN-3515

10.40

11.68

50

740

blue

DN-3516

11.69

13.11

70

25

790

Orange

35

DN-3517

13.12

14.66

50

860

purple

DN-3100

14.67

16.59

95

70

889

blue

120

DN-3101

16.60

18.77

150

95

980

red

DN-3102

18.78

21.26

185

120

1016

Brown

TC-07

150

DN-3103

21.27

24.05

240

185

1016

green

TC-12

DN-3104

24.06

27.20

240

1016

black

300

Table 1-4 Selection table of strain clamp for pre-twisted insulated conductors (2)

Product number

Applicable wire diameter range (mm)

Applicable wire model below 1kV

GB12527-90

Applicable wire model below 10kV

GB 14049-93 thin insulation

Reference length

(mm)

Color code

Mininum

Maximum

NL-35/JY

14.67

16.59

35

889

blue

TC-05

NL-50/JY

50

NL-70/JY

16.60

18.77

70

980

red

NL-95/JY

18.78

21.26

95

1016

Brown

TC-07

NL-120/JY

120

NL-150/JY

21.27

24.05

150

1016

green

TC-12

NL-185/JY

24.06

27.20

185

1016

black

NL-240/JY

240

NL-300/JY

27.21

30.78

300

1016

purple

Note: The meaning of letters and numbers in the model: N- strain clamp; L- spiral pre-twisted type: “-” is the applicable wire model JY- insulated wire.
The selection of the TCB model of the optional matching hardware is related to the rated breaking force of the wire.
The selection of strain clamp is subject to the actual wire diameter.

Table 1-5 Selection table of pre-stranded conductor strain clamp (for steel core aluminum stranded wire)

Product number

Applicable wire diameter range (mm)

Applicable wire model below 1kV

GB12527-90

Reference length

(mm)

Clamp weight (kg)

Color code

Optional matching hardware

Minimum

maximum

NL-16/3

5.17

5.79

16/3

444

0.1

Brown

TC-05

NL-25/4

6.54

7.34

25/4

546

0.1

yellow

NL-35/6

7.35

8.26

35/6

622

0.2

red

NL-50/8

9.26

10.39

50/8

685

0.2

yellow

NL-70/10

10.40

11.68

70/10

736

0.3

blue

NL95/15

13.12

14.66

95/15

876

0.6

red

TC-07

NL-95/20

95/20

NL-120/7

120/7

NL-120/20

14.67

16.59

120/20

889

0.8

black

NL-120/25

120/25

TC-12

NL-150/8

150/8

NL-150/20

16.60

18.77

150/20

1016

1.1

green

NL-150/25

150/25

NL-150/35

150/35

NL-185/10

185/10

NL-185/25

18.78

21.26

185/25

1155

1.7

Orange

NL-185/30

185/30

NL-185/45

185/45

NL-210/10

210/10

NL-210/25

210/25

NL-210/35

210/35

NL-210/50

210/50

NL-240/30

21.27

24.05

240/30

1270

2.3

blue

TC-16

NL-240/40

240/40

NL-300/15

300/15

NL-300/20

300/20

NL-300/25

24.06

27.20

300/25

1442

3.0

Brown

NL-300/40

300/40

NL-300/50

300/50

Note: The meaning of letters and numbers in the model: N- tension clamp; L- spiral pre-twisted type; after “-” is the applicable wire model; LGJ- steel core aluminum stranded wire.
This table only lists some products. If you need products with other specifications, please consult the company.
In principle, pre-twisted conductor strain clamps are only used in overhead lines with voltage levels of 110kV and below.

Table 1-6 Selection table of pre-twisted wire tension clamp (for aluminum stranded wire)

Product number

Applicable wire diameter range (mm)

Applicable wire type (GB1179-83)

Aluminum stranded wire (LJ)

Reference length

(mm)

Clamp weight

Color code

Optional matching hardware

Minimum

Maximum

NL-16/LJ

4.62

5.16

16

406

0.1

blue

TC-05

NL-25/LJ

5.80

6.53

25

444

0.1

Orange

NL-35/LJ

7.35

8.26

35

622

0.2

red

TC-07

NL-50/LJ

8.27

9.25

50

685

0.2

green

TC-12

NL-70/LJ

10.40

11.68

70

736

0.4

blue

NL-95/LJ

11.69

13.22

95

800

0.4

Orange

NL-120/LJ

13.12

14.66

120

876

0.6

red

NL-150/LJ

14.67

16.59

150

889

0.8

black

NL-185/LJ

16.60

18.77

185

1016

1.1

green

NL-210/LJ

16.60

18.77

210

1016

1.1

green

NL-240/LJ

18.78

21.26

240

1155

1.7

Orange

NL-300/LJ

21.27

24.05

300

1270

2.3

blue

TC-16

NL-400/LJ

24.06

27.20

400

1422

3.0

Brown

NL-500/LJ

27.21

30.78

500

1651

4.9

Orange

Note: The meaning of letters and numbers in the model: N- tensile clamp; L- spiral pre-twisted type: “One” is the applicable wire model; LJ- aluminum stranded wire.
This table only lists some products. If you need products with other specifications, please consult the company.


  • Previous: