JJCD/JJCD10 velit penetrans grounding fibulae

Description:

Magna intentione 10kV Insulation Piercing Connector cum duobus circulis Grounding pro protectione Earthing

Descriptio

10kv duo fulmina velit transfixa cum connectore terreno Ringo pro Protection terrestri ac temporaria Inspectionis Electricae. Apta est pluribus generibus ABC conductoribus necnon nexus ad servitium et funem nucleorum accendentium.Cum seras constringunt, dentes laminarum contactuum insulationem penetrant et contactum perfectum constituunt.Claustra constringuntur donec capita tondent.Aureus tensus praestatur (fuse nut).Nulla vitae spoliatio vitatur.

Servitii condicio: 400/600V, 50/60Hz, -10°C ad 55°C

Standard: IEC 61284, EN 50483, IRAM2435, NFC33 020.

Aluminium et aeris conductores idoneum


Product Detail

Product Tags

Overview

10kv duo fulmina velit transfixa cum connectore terreno Ringo pro Protection terrestri ac temporaria Inspectionis Electricae. Apta est pluribus generibus ABC conductoribus necnon nexus ad servitium et funem nucleorum accendentium.Cum seras constringunt, dentes laminarum contactuum insulationem penetrant et contactum perfectum constituunt.Claustra constringuntur donec capita tondent.Aureus tensus praestatur (fuse nut).Nulla vitae spoliatio vitatur.

Servitii condicio: 400/600V, 50/60Hz, -10°C ad 55°C

Standard: IEC 61284, EN 50483, IRAM2435, NFC33 020.

Aluminium et aeris conductores idoneum

Features

• Exertus de watertightness ad intentionem 6 kv pro 30 min in waterbath
• Potentia libera constringendi fulmina permittit tutum officinae in vita lineae
• Bimetallic, aluminio et conductori aeneo idoneo
• Long collum 13 mm tondendum caput nut curandum officinae certae
• Components non losable, finem pileum corpori affixum
• Insulation materia tempestatum facta et UV resistens fibra vitrea polymerum aucta

1kV penetrabile grounding Fibulae lectio mensa

Apta est 1kV capitis insulae conductoris fundationis tutelae et inspectionis electricae temporalis.

exemplar

Aequivalent exemplum

Applicatur voltage

Lorem filum

Praecipuae dimensiones (mm)

Nominal current

Numerus ictuum

Puncta profundum

kV)

(mm²)

A

B

H

(A)

Picies)

(mm)

WXF1-95/16

JJCD1-16-95

1

16-95

120

103

80

214

1

3-4

WXF1-120/35

JJCD1-35-120

1

35-120

120

103

80

316

2

3-4

WXF1-150/50

JJCD1-50-150

1

50-150

120

103

80

316

1

3-4

WXF1-185/95

JJCD1-95-185

1

95-185

125

103

110

276

1

3-4

WXF1-240/150

JJCD1-150-240

1

150-240

125

103

110

276

1

3-4

10kV punctura grounding Fibulae lectio mensa

Apta est ad 10kV capitis conductoris insulatae fundationis tutelae et inspectionis electricae temporalis.

exemplar

Aequivalent exemplum

Applicatur voltage

Lorem filum

Praecipuae dimensiones (mm)

Nominal current

Numerus ictuum

Puncta profundum

kV)

(mm²)

A

B

H

(A)

Picies)

(mm)

WXF10-95/25

10

25-95

154

120

110

276

1

3-4

WXF10-95/25

JJCD10-95-25

10

25-95

144.5

140

92.5

257

2

4-5

WXF10-120/35

JJCD10-120-35

10

35-120

148

120

86

316

2

4-5

WXF10-185/95

JJCD10-95-185

10

95-185

152

140

112.5

476

2

4-5

WXF10-240/150

JJCD10-150-240

10

150-240

160

140

1125

476

2

4-5

10kV piercing grounding clamp 00

10kV piercing grounding clamp 01

10kV distributio recta grounding fibulae

Apta 10kV distributio recta grounding praesidium

exemplar

Aequivalent exemplum

Applicatur voltage

Lorem filum

Praecipuae dimensiones (mm)

Nominal current

Numerus ictuum

Puncta profundum

kV)

(mm²)

A

B

H

(A)

Picies)

(mm)

WXF10-95/25(Match)

Parvus-match)

10

25-95

148

138

86

316

1

3-4

WXF10-95/25(Match)

JJCD10-95-25(Match)

10

25-95

148.5

140

98

257

2

4-5

WXF10-120/35(Match)

JJCD10-120-35(Match)

10

35-120

154

138

110

276

2

4-5

WXF10-185/95(Match)

JJCD10-95-185(Match)

10

95-185

152

140

113

476

2

4-5

WXF10-240/150(Match)

JJCD10-150-240(Match)

10

150-240

160

140

113

476

2

4-5

 

10kV piercing grounding clamp 0

10kV distribution line grounding clamp 02


  • Previous:
  • Deinde:

  • Related Products