1KV 10KV insulation piercing clamp

Short Description:

Insulation Piercing Connector IPC connector is suitable for aluminum and copper conductors and components not losable, end cap attached to body, Insulation material made of weather resistant glass fiber reinforced polymer, contact teeth made of tinned brass or copper or aluminum, bolt made of dacromet steel. When tightening the bolts, the teeth of the contact plates penetrate the insulation and establish a perfect contact. The bolts are tightened until the heads shear off. Stripping of insulation is avoided.


Product Detail

Product Tags

Overview

▪ Piercing structure, simple installation, no need to strip insulated wires;
▪ Torque nut, constant puncture pressure, to ensure a good electrical connection without damaging the wire;
▪ Self-sealing structure, moisture-proof, waterproof, anti-corrosion, prolong the service life of insulated wires and clamps;
▪ Use special contact blades, suitable for copper (aluminum) butt joint and copper-aluminum transition;
▪ The electrical contact resistance is small, and the contact resistance is less than 2.5 times the resistance of the equal-length branch wire, which meets the DL/T765.1-2001 standard;
▪ Special insulating shell, resistant to sunlight and environmental aging, dielectric strength> 12kV;
▪ Curved surface design, suitable for the same (different) diameter wire connection, wide connection range (0.75mm2-400mm2/td)

Product performance test

▪ Mechanical properties: The gripping force of the clamp is greater than 1/10 of the wire breaking force, which meets the requirements of GB/T2314-2008;
▪ Temperature rise performance: In the case of high current, the temperature rise of the wire clamp is less than the temperature rise of the connecting wire:
▪ Thermal cycle performance: Meet the GB/T2317.3-2008 thermal cycle test standard for electric power fittings;
▪ Waterproof insulation performance: meet the relevant test requirements of GB/T13140.1-2008 Part 2;
▪ Corrosion resistance: 3 cycles of 14 days test in sulfur dioxide and salt spray environment;
▪ Environmental aging performance: six weeks of exposure to temperature changes and thermal shocks in ultraviolet, dry and humid environments;
▪ Fire resistance: The insulating material of the connecting device can withstand the glow wire test and meet the requirements of Chapter 4~10 of GB/T5169.4.

Selection table

1kV series product selection table

model

Equivalent model

Main line section

(mm²)

Branch section

(mm²)

Nominal current

(A)

Dimensions

(mm)

Weight (g)

Puncture depth

(mm)

Number of bolts

(Pieces)

WX756

JJC888

0.75-6

0.75-6

41

21×27×23

10

1-1.5

1

WX101

JJC-1

1.5-25

1.5-10

55

27×41×62

55

1.5-2

1

WXEP

JJC-2

16-95

1.5-10

55

27×41×62

55

1-2

1

WX102

JJC-3(A)

6-50

4-25

157

42×45×62

110

2.5-3.5

1

WX2-95

JJC-3

16-95

4-35(50)

157

46×52×87

160

2.5-3.5

1

WX2-150

JJC-4

50-150

6-35(50)

157

46×52×87

162

2.5-3.5

1

WX3-95

JJC-5

25-95

25-95

214

50×61×l00

198

3-4

1

WX3-120

JJC-5-1

16-120

16-120

214

50×61×l00

198

3-4

1

WX4-150

JJC-6

(35)50-150

(35)50-150

316

50×61×l00

280

3-4

1

WX6

JJC-7

120-240

25-120

276

52×68×l00

360

3-4

1

WX7

JJC-7-1

150-240

10-25

102

52×68×l00

336

3-4

1

WX240

JJC-8

95-240

95-240

425

83×130×130

1020

4-5

2

WX300

300

25-95

425

83×130×130

1040

4.5-5.5

2

95-240

WX400

400

25-95

425

83×130×130

1050

5-6

2

95-240

Flame-retardant and fire-resistant piercing clamp selection table

model

Equivalent model

Main line section

(mm²)

Branch section

(mm²)

Nominal current

(A)

Dimensions

(mm)

Weight (g)

Puncture depth

(mm)

Number of bolts

(Pieces)

WX756

JJC888

0.75-6

0.75-6

41

21×27×23

10

1-1.5

1

WX101

JJC-1

1.5-25

1.5-10

55

27×41×62

55

1.5-2

1

WXEP

JJC-2

16-95

1.5-10

55

27×41×62

55

1-2

1

WX102

JJC-3-1

6-50

4-25

157

42×45×62

110

2.5-3.5

1

WX2-95

JJC-3

16-95

4-35(50)

157

46×52×87

160

2.5-3.5

1

WX2-150

JJC-4

50-150

6-35(50)

157

46×52×87

162

2.5-3.5

1

WX3-95

JJC-5

25-95

25-95

214

50×61×l00

198

3-4

1

WX3-120

JJC-5-1

16-120

16-120

214

50×61×l00

198

3-4

1

WX4-150

JJC-6

(35)50-150

(35)50-150

316

50×61×l00

280

3-4

1

WX6

JJC-7

120-240

25-120

276

52×68×l00

360

3-4

1

WX7

JJC-7-1

150-240

10-25

102

52×68×l00

336

3-4

1

WX240

JJC-8

95-240

95-240

425

83×130×130

1020

4-5

2

WX300

300

25-95

425

83×130×130

1040

4.5-5.5

2

95-240

WX400

400

25-95

425

83×130×130

1050

5-6

2

95-240

10kV Piercing Clamp Selection Table

model

Equivalent model

Applicable wire (mm²)

外形尺寸(mm)

Nominal current

(A)

Number of bolts

(Pieces)

Puncture depth

(mm)

Main line section
(mm²)

Branch section

(mm²)

A

B

H

WX10-95/70

JJC10-1

25-95

16-70

68

82.5

107.5

226

2

4.5-6

WX10-185/50

JJC10-2

95-185

16-50

78.5

77.5

112.5

180

2

4.5-6

WX10-240/150

JJC10-3

95-240

50-150

84

83

112.5

366

2

4.5-6

WX10-240/240

JJC10-4

95-240

95-240

89

85.5

112.5

530

2

4.5-6